AIM
For effective inhaler training on dry powder and metered dose inhalers
The unique Vitalograph AIM™ (Aerosol Inhalation Monitor) is designed to assist medical practitioners in assessing inhaler use, whether MDI or DPI. Mastery of the correct technique will support more accurate drug delivery and good patient compliance, resulting in better disease management and fewer visits to medical professionals.
-
Blue BVF 28350 (Bacterial Viral Filter)
Blue BVF Bacterial Viral Filters – fits Vitalograph, round mouthpiece. Box of 50
Vitalograph Bacterial Viral FiltersTM (BVF) provide an efficient hygiene solution giving better than 99.999% cross-contamination efficiency, protecting the patient, operator and equipment from cross infection and contamination during pulmonary function testing.
Suitable for inspiratory and expiratory spirometry testing, these single-use bacterial viral filters provide effective protection from cross infection. Vitalograph BVFs feature an electrostatically charged barrier that filters droplets, aerosols, bacteria and viruses out of the airstream. When a new BVF is used for every patient, the interior of the device is protected, meaning that only exterior surface cleaning should be required. Improved hygiene can lead to lower running costs.
A wide range of BVFs are available to fit all leading makes of spirometers and PFT equipment. These may be purchased as standalone filters or in a kit with BVF, bite-on mouthpiece and noseclip options.
-
myPEF
The only web enabled peak flow meter
The myPEF peak flow meter combines high quality and attractive styling with great value. This robust and easy to clean peak flow meter conforms to the ISO standard for Peak Expiratory Flow Meters.
The myPEF is supplied with a unique ID card allowing users free access to a secure website where they can enter their PEF readings, eliminating the need for paper records and supporting data accuracy and effective asthma management. Suitable for use with any web enabled device.
-
AsmaPLAN & AsmaPLAN+
The simple, accurate way to monitor asthma
The patented dual color sliders on the asmaPLAN+™ define the management color zones set by the healthcare professional for the asthmatic to follow.
100% is the asthmatic’s best. The yellow zone will typically be set to start at 80% of the asthmatic’s best while the red zone will typically start at 60%. Variability of PEFR of greater than 20% should alert the asthmatic to a possible asthma attack.
-
SafeTway Mouthpieces
SafeTway Mouthpieces are disposable mouthpieces with One Way Valve that allows entry of expired air into the measuring system but not back to the test subject. This simple yet effective patented design prevents concerns of accidental inhalation of pathogens. These low cost and low resistance mouthpieces that helps to prevent cross-infection and can be used with most peak flow meters and spirometers.
It has a 30mm diameter at both ends. It fits most pulmonary function test equipment, including peak flow meters. An adaptor may be required for some models not accepting 30mm diameter mouthpiece.
Features
- Protects the subject from cross-infection
- One-way valve prevents inhalation respiratory manoeuvre
- Suitable for expiratory manoeuvres with peak flow meters and spirometers
- Completely disposable
-
Thermal Printer Paper for ALPHA & ALPHA Touch Spirometers
Thermal Printer Paper, 111mm x 48mm diameter (5 rolls), for ALPHA & ALPHA Touch spirometers
Replacement paper for high quality printing and trouble-free printer operation from Vitalograph devices with integrated print capability.
5 rolls.
-
Precision Syringes
For peace of mind regarding the accuracy of your spirometer
Vitalograph precision syringes provide quick and easy accuracy checks with reliability and fast verification.
Our precision syringes are available as a simple 3-L or a valved 1-L type. The 3-L precision syringe is for all spirometers as required by ISO 26782:2009. It can be used with flow or volume sensor systems and is compatible with any manufacturers’ equipment. A range of adaptors are available. The 1-L Precision Syringe is for linearity checking volume displacement spirometers
-
Noseclips
Designed for comfort and performance during spirometry testing
These nose clips are ergonomically designed for comfort and are in line with international spirometry guidelines which recommend the use of nose clips during spirometry testing.
-
Bite-on and Oval mouthpieces
Designed for comfort and performance
These ergonomically designed mouthpieces offer a choice of fit for adults and children.
-
Eco BVF (Bacterial Viral Filter)
Optimal protection for patients, staff and equipment during pulmonary function testing.
Validated cross-contamination efficiency >99.999%.
Traps expectorated matter, bacteria and viruses.
The Vitalograph Eco BVF™ range protects patients, medical personnel and equipment from cross infection and contamination during pulmonary function testing.Eco BVFs combine independently validated 99.999% bacterial and viral cross-contamination efficiency for medical personnel, patients and equipment, with a reduced environmental impact because less plastic used in manufacturing. The electrostatically charged barrier filters droplets, aerosols, bacteria and viruses out of the airstream. When a new BVF is used for every patient the interior of the device is protected so only exterior surface should require cleaning.
Kits are available including Eco BVF, nose clip and bite on mouthpiece combination options. The range also includes an extended ‘Bite-Lip’ design. Adaptors are available to fit most devices.
-
Lung Monitor usb
For the home monitoring of FEV1, FEV6 & the ratio with electronic & hard copy reports
The lung monitor USB combines all of the features of the lung monitor with the ability to link to your PC. Session data and device ID may be transmitted to Vitalograph Reports or an API developers’ kit is available for providers of e-Diary, home hub and telemedicine solutions.
-
Lung monitor
Vitalograph lung monitor is a easy to use home monitoring device which records lung function parameters
Easy to use device for monitoring of lung function parameters for those with respiratory conditions including cystic fibrosis and transplant patients. The lung monitor measures FEV1, FEV6 & the ratio with electronic and hard copy reports. The device is simple to use and stores over 200 test sessions.